Treadmill Ergometer PPS Medical Series PPS 43 Plus PPS 55 Plus PPS 70 Plus PPS 43 Med PPS 55 Med PPS 70 Med PPS 43 Med-i PPS 55 Med-i PPS
Safety 10 05/2013-v1.0en 3.3 Markings on Device Safety relevant information is identified on the device using the following symbols: Protective Gr
Safety 05/2013-v1.0en 11 3.4 Personnel Qualifications and Responsibilities WARNING Danger Due to Improper Use! Improper handling of the device ca
Safety 12 05/2013-v1.0en In all fields of use the treatment of patients with a variety of physical and/or mental limitations is carried out (for exam
Safety 05/2013-v1.0en 13 In the following cases treadmill training may only be carried out after consultation with a doctor: Pregnancy acute t
Safety 14 05/2013-v1.0en 3.7 Electromagnetic Compatibility (EMC) It is expressly noted that ELECTRICAL MEDICAL EQUIPMENT is subject to special preca
Technical Data 05/2013-v1.0en 15 4 Technical Data 4.1 Name Plate The nameplate contains the device's main technical details. For service ques
Technical Data 16 05/2013-v1.0en 4.3 Technical Specifications Device designation: Model: PPS 43 Model: PPS 55 Model: PPS 70 Walking surface (L x
Transportation and Storage 05/2013-v1.0en 17 5 Transportation and Storage 5.1 Safety Notices for Transportation Check the treadmill for damage up
Transportation and Storage 18 05/2013-v1.0en 5.4 Transportation with Carrying Poles Four carrying poles (square steel pipes) are included as treadmi
Transportation and Storage 05/2013-v1.0en 19 5.5 Removing / Mounting Side Handrails In most cases the WOODWAY is delivered completely assembled. In
European Representative: Manufacturer: WOODWAY GmbH Steinackerstr. 20 79576 Weil am Rhein Germany WOODWAY USA, Inc. W229 N5
Transportation and Storage 20 05/2013-v1.0en Fig. 6 Remove electronics shielding panel Disconnect cables from display cable, emergency stop cable
Transportation and Storage 05/2013-v1.0en 21 Fig. 8 Treadmill controls (WLS) Now carefully pull the harness through the hole below the toroidal tr
Transportation and Storage 22 05/2013-v1.0en Fig. 10 Fixing bolts in railing mount PPS Ortho / PPS Med PPS Plus: Loosen the base frame mount using
Transportation and Storage 05/2013-v1.0en 23 Mounting the railing 1. Mounting of the railing is carried in the opposite order. 2. The following
Product Description 24 05/2013-v1.0en 6 Product Description 6.1 Overview of Models WOODWAY slat-belt treadmills are available in the following wal
Product Description 05/2013-v1.0en 25 6.2 Equipment and Options WOODWAY slat-belt treadmills are available in the following walking surface widths:
Product Description 26 05/2013-v1.0en 6.3 Main Components The main components are shown using the PPS Plus model: Fig. 12 Device components, PPS P
Product Description 05/2013-v1.0en 27 The support system consists of two supporting rails (secondary carrier), which are equipped with high-performa
Product Description 28 05/2013-v1.0en 6.5 Control and Display Elements The WOODWAY user system (WUS) is equipped with an LCD touch panel, which prov
Product Description 05/2013-v1.0en 29 The external WOODWAY user system (WUS), with emergency stop switch, is an optional WUS display as a desktop un
Table of Contents 05/2013-v1.0en 3 1 Table of Contents 1 Table of Contents ...
Product Description 30 05/2013-v1.0en 6.6 Safety Equipment The medical PPC series treadmills are equipped with different safety equipment de-pending
Product Description 05/2013-v1.0en 31 On treadmills with a reverse direction function, the emergency stop button has a magnetic mount and can be fre
Product Description 32 05/2013-v1.0en Fig. 19 Emergency stop magnetic switch on the display 1. Clothing clip 2. Pull cord, adjustable length 3.
Product Description 05/2013-v1.0en 33 Provided the device is equipped with fall protection with emergency stop and the runner is secured by chest ha
Commissioning 34 05/2013-v1.0en 7 Commissioning 7.1 General Commissioning is the initial intended use of the device, see sec. 3.5 Page 11. En-sure
Commissioning 05/2013-v1.0en 35 The following further instructions for installation are to be observed: When installed on upper floors, the devic
Commissioning 36 05/2013-v1.0en After positioning the device at the installation site, adjust the horizontal height using a level. The height of the
Commissioning 05/2013-v1.0en 37 7.3 Electrical Connection DANGER Danger of Death by Electric Shock! Improper handling of electrical equipment by
Commissioning 38 05/2013-v1.0en Ungrounded outlets may NOT be used! The use of power strips is not permitted! WARNING Danger of Injury by Tripping
Operation 05/2013-v1.0en 39 8 Operation WARNING Danger Through Uncontrolled Running Surface Movement! By stepping on the rear most part of the ru
Table of Contents 4 05/2013-v1.0en 8 Operation ... 398.1
Operation 40 05/2013-v1.0en 8.2 Application Possibilities for Children Due to their design and operation, PPS series slat-belt treadmills are only f
Operation 05/2013-v1.0en 41 8.4 Switching Device On/Off NOTE Ensure that NO emergency stop button or emergency stop mushroom is engaged. The emerg
Operation 42 05/2013-v1.0en 5. Switch the device off via the main switch on the power supply console when it will not be used for a long time. Fig.
Operation 05/2013-v1.0en 43 8.5 Using the Keypad The keypad can be attached to a suitable point on the handrail so that the controls are easily acc
Operation 44 05/2013-v1.0en 8.6 Operating the Data Monitor (DaMo) The data monitor has 4 multi-digit displays to indicate the current training param
Operation 05/2013-v1.0en 45 In the display (Pos. 9) the distance in kilometers and calorie consumption of the runner since the last time the treadmi
Operation 46 05/2013-v1.0en 8.7 Operation with Woodway User System (WUS) The WOODWAY user system (WUS) is used to display the current parameters, th
Operation 05/2013-v1.0en 47 By pressing the green button on the right side of the display (Pos. 4), the treadmill is turned on. After the initializa
Operation 48 05/2013-v1.0en In manual mode the following values appear in the display. Speed, in either km/h or miles/h or m/s Current incline
Operation 05/2013-v1.0en 49 A vertical line moves from left to right and shows you your position in the program. In addition, you see the following
Introduction 05/2013-v1.0en 5 2 Introduction 2.1 Operating Instructions Information This manual provides information on the safe operation of the
Operation 50 05/2013-v1.0en The selected program can be edited here: Fig. 34 WUS edit program Changes the respective program steps The parameter t
Operation 05/2013-v1.0en 51 8.7.4 Create Program The process for creating a new program corresponds to the process for editing an existing program.
Operation 52 05/2013-v1.0en After selecting a program, the following screen appears: Fig. 37 WUS pulse control Here, you must first enter the age u
Operation 05/2013-v1.0en 53 8.7.6 Edit/Show Parameters To change parameters select the "EDIT PARAMETERS" option in the start menu. Fields
Operation 54 05/2013-v1.0en 8.8 Adjustment of Bar Rails PPS Plus type treadmills are equipped with bar railing. The PPS and PPS Med Ortho models ar
Operation 05/2013-v1.0en 55 8.9 Reversing the Direction Depending on the model, the treadmill has a reversing direction function, or can be retrofi
Operation 56 05/2013-v1.0en 8.10 Body Weight Support Systems Depending on the illness may be necessary to use a body weight support system for the t
Options and Accessories 05/2013-v1.0en 57 9 Options and Accessories 9.1 Order Numbers The following accessories and options can be obtained from a
Options and Accessories 58 05/2013-v1.0en 9.2 Video Railing for PPS Ortho The cross member on the front part of the PPS Ortho handrail can be remove
Options and Accessories 05/2013-v1.0en 59 Fig. 45 PPS Ortho video railing 1. Incorrect lever position of the quick disconnect, danger of injury!
Introduction 6 05/2013-v1.0en 2.3 Copyright The release of the operating instructions to third parties without the written permis-sion of WOODWAY Gm
Options and Accessories 60 05/2013-v1.0en Following further safety measures must be considered: 1. Before using the treadmill, the mounting aid must
Options and Accessories 05/2013-v1.0en 61 9.5 USB to Serial Converter A "USB to Serial" adapter allows the connection of devices with ser
Options and Accessories 62 05/2013-v1.0en 9.6 Interface Wire To control the treadmill via PC or laptop the serial interface of the treadmill must be
Maintenance and Cleaning 05/2013-v1.0en 63 10 Maintenance and Cleaning WARNING Danger of Injury due to Lack of Qualifications! If maintenance or
Maintenance and Cleaning 64 05/2013-v1.0en For cleaning and disinfection of parts that are touched (handrail, display, controls, etc.) a formaldehyde
Maintenance and Cleaning 05/2013-v1.0en 65 A complete function test the treadmill must be carried out every 2-4 weeks depending on the duration and
Maintenance and Cleaning 66 05/2013-v1.0en A repair must take place: if liquid has gotten into the device, with damaged power cord (cable, plug
Maintenance and Cleaning 05/2013-v1.0en 67 10.3 Technical Safety Checks (TSC) Medical PPS series treadmills are devices in protection class I and h
Maintenance and Cleaning 68 05/2013-v1.0en According to section 5.2 of the standard EN 62353, an inspection is carried out visually prior to the meas
Maintenance and Cleaning 05/2013-v1.0en 69 A measurement of the insulation resistance in accordance with section 5.3.4 of the standard may NOT be pe
Introduction 05/2013-v1.0en 7 2.5 Customer Service For service questions, please contact as follows: WOODWAY GmbH Steinackerstr. 20 79576 Weil am
Maintenance and Cleaning 70 05/2013-v1.0en Technical safety checks (after repeat tests or testing after maintenance and repair) may only be performed
Maintenance and Cleaning 05/2013-v1.0en 71 The removal of the power plug from the outlet alone is not sufficient for the disa-bling of the treadmill,
Maintenance and Cleaning 72 05/2013-v1.0en 10.5 Device Fuses The fuses must comply with the published technical specifications, see sec. 4.3 Page 16
Troubleshooting 05/2013-v1.0en 73 11 Troubleshooting ATTENTION With the exception of the maintenance work described in this chapter, the treadmill
Troubleshooting 74 05/2013-v1.0en 11.2 No Display If the display is not lit when you turn the treadmill, check the following points: Is the emer
Troubleshooting 05/2013-v1.0en 75 11.6 Serial RS-232 Interface Possible causes of a serial interface malfunction are: Defective wire connection
Disposal 76 05/2013-v1.0en 12 Disposal The disposal of the equipment must be in accordance with the respective national regulations. Electrical and
Instruction Record 05/2013-v1.0en 77 13 Instruction Record Once the introduction, installation and functional check of the slat belt treadmill has
Instruction Record 78 05/2013-v1.0en Step Description Conducted 13 Notice to the RS232 port and CD with treadmill control software, as well as the
Instruction Record 05/2013-v1.0en 79 Confirmation of commissioning and training record With the signing of the instruction record, the instructor an
Introduction 8 05/2013-v1.0en 2.6 EC Declaration of Conformity Fig. 1 CE Declaration of Conformity
Declaration of Conformity with Technical Regulations 80 05/2013-v1.0en 14 Declaration of Conformity with Technical Regulations WOODWAY hereby confir
Table of Figures 05/2013-v1.0en 81 15 Table of Figures Fig. 1 CE Declaration of Conformity ...
Table of Figures 82 05/2013-v1.0en Fig. 49 USB Interface wire RS-232 (2 × D-SUB 9-pin), configuration "minimum" null-modem wire ...
Safety 05/2013-v1.0en 9 3 Safety 3.1 General PPS series treadmills have been reliably designed, manufactured and tested accord-ing to the latest s
Kommentare zu diesen Handbüchern